Precautions for the use of 18650 battery film machine equipment
by:Vglory
2021-03-02
Precautions for the use of 18650 battery cover machine 1. When starting the 18650 battery shell membrane machine, check whether the initial position of the actuator device for each action, admit that there is no debris on other equipment, turn the air source, and admit that the air source pressure is 0.5-- 0.6mpa, then hand over the power operation control program: 2. Turn off the power and air source after the equipment is stopped: 3. Turn off the power and air source when repairing, maintaining and maintaining the equipment: 4. When sub-packing the battery into the charging box, try your best Ensure that the positive and negative directions of all batteries are in the same direction: When the battery in the charging box is about to be fully charged, remove the batteries in time: 5. When the machine is running, do not put your hands in the battery sorting track to avoid hurting your fingers: 6. When the device is running For abnormalities or pause reasons, you should first press the stop button, then check the abnormal condition of the equipment, troubleshoot, release the stop button, and let the robot return to the original point, the system is in a pause state, and then press the green button to start, so that the system resumes active operation , If the system operation cannot be restored to normal operation according to the system reset button. 7. When the sorting of a certain type of battery is completed and there is no material alarm, press the green button for 3 seconds to make the material empty. Maybe 30 seconds later, the system will take the initiative to enter the final form and take the initiative to sort the remaining materials into the material tank. 8. Before each operation of the 18650 sheathing machine, remove the battery from the sorter, press the system reset button to make the device enter the initial state, and then press the operating button: 9. Make sure the positive and negative electrodes of the sorted battery in the 18650 battery cover The terminal is cleaned to prevent dust and other debris from polluting the detection probe to ensure the accuracy of the measurement data: 10. To ensure the accuracy of the measurement, it is recommended to clean the probe with alcohol every 4 hours under normal processing conditions and replace the probe once a month: 11. To ensure the high-precision measurement of the instrument, please reset and calibrate the instrument regularly. Disclaimer: Some pictures and content of the articles published on this site are from the Internet. If there is any infringement, please contact to delete. Previous: Analysis of maintenance methods for lithium batteries
Custom message
Related Products