What are the requirements of the lithium battery system for BMS batteries
by:Vglory 2021-03-28
The lithium battery system has the following eight requirements for the BMS battery: 1. Cell equalization voltage: When the cell voltage is greater than this value, the equalization is turned on; 2. The charging voltage is restored: After the charging protection, when the highest cell voltage is greater than this value, Resume charging; 3. Resume discharge voltage: After discharge protection, when the lowest cell voltage is greater than this value, discharge will resume; 4. System shutdown cell value: When the lowest cell is less than this value, the system will automatically power off and shut down; 5. Highest Single level alarm value: the highest single level alarm value; 6. Highest single level secondary alarm value: when the highest single unit is greater than this value, a secondary alarm occurs, and then the charging contactor is disconnected; 7. The lowest unit The first level alarm value: the lowest single level alarm value; 8. The lowest single level second alarm value: when the lowest single unit is less than this value, a second level alarm occurs, and then the discharge contactor is disconnected. Disclaimer: Some pictures and content of articles published on this site are from the Internet. If there is any infringement, please contact to delete. Previous: What are the processes for the production of lithium batteries