Analyze UPS battery safety operation specifications and precautions for charging
by:Vglory 2021-04-21
UPS battery safety operation specifications When using UPS batteries, you must first know the performance of the battery, because the battery installation requires certain skills, and at the same time, you must also pay attention to operational considerations in order to better master this knowledge and make better use of it. . As a charging and discharging power supply equipment, UPS batteries are often used in our daily work. The battery contains electrolyte, which is a dangerous chemical substance. In daily use, pay attention to some operating specifications to improve work efficiency. 1. It is strictly forbidden to pour pure water straight into the sulfuric acid to guard against the sudden increase in the temperature of the pages, which may cause splashes of concentrated sulfuric acid. 2. UPS battery maintenance personnel must wear acid-resistant protective equipment such as protective glasses, rubber gloves, aprons and rubber shoes to guard against sulfuric acid corrosion and burns. 3. It is strictly forbidden to place conductive objects on the UPS battery pack. The operator must remove possible conductive objects such as watches before work to guard against sparks or explosions caused by external short-circuits of the battery. 4. When loading and unloading the UPS battery pack, a lifting device with corresponding weight must be used. During the hoisting process, the battery must not be placed under the battery pack to prevent the battery pack from falling. 5. Smoking, open flames, static sparks, etc. are strictly prohibited in the battery charging place to beware of a small amount of hydrogen explosion during battery charging. 6. The temperature of the battery should not exceed 55°C, otherwise the life of the UPS battery will be reduced. Therefore, the temperature at the start of charging must be lower than 45°C. If the temperature is higher than 45°C, wait until it cools down before charging. Precautions for UPS battery charging When charging, you should open the filling hole cover of the UPS battery and keep the room well ventilated to avoid the danger of releasing a large amount of gas when the charging ends. When charging, it is strictly prohibited to smoke or fire, and beware of the combustion of the gas released during charging. When charging, you should first connect the positive and negative cables between the UPS battery and the charger, and then turn on the charger's power supply. Otherwise, sparks may occur when the cables are connected, which may cause an explosion. The charger is generally connected to a 380v power supply, so be sure to pay attention to safety when moving or charging. The UPS battery charging guard is used in direct sunlight or in the open rain, and guards against working in a dusty or corrosive gas environment. Disclaimer: Some pictures and content of articles published on this site are from the Internet. If there is any infringement, please contact to delete. Previous: How to deal with the health of used batteries after garbage classification?
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist